The remote cable is usually in the form of a full medium, that is, a non-metallic reinforcement is used. Since the BBU+RRU remote base station has small requirements on the number of cores of the optical cable, it is flexible in combination, and an optical hybrid structure can also be used in individual scenarios. In order to reduce the diameter of the optical cable, the cable is generally extended. The use of tight- fitting optical fiber can further improve the tensile and anti-pressure performance of the optical fiber , and facilitate the end-to-end processing with the quick connector. The reinforcing member adopts aramid yarn, which can improve the short-term tensile force and flexibility of the optical cable, considering The cable is used in indoors, so the jacket is made of LZSH sheathing material.
Features and applications
● Convenient construction and efficient installation; Energy saving and environmental protection, reducing costs;
● The power supply is stable, the power supply comes from the equipment room, and is isolated from the mains, effectively eliminating power outages;
● Safe and reliable, no leakage risk, can be automatically cut off, such as short circuit, open circuit.
Fiber characteristics
G.652.D | G.657A2 | 50/125μm | 62.5/125μm | ||
attenuation | @850nm | - | - | ≤3.0dB/km | ≤3.0dB/km |
@1300nm | - | - | ≤1.0dB/km | ≤1.0dB/km | |
@1310nm | ≤0.36dB/km | ≤0.36dB/km | - | - | |
@1550nm | ≤0.22dB/km | ≤0.23dB/km | - | - | |
bandwidth | @850nm | - | - | ≥500MHz·km | ≥200MHz·km |
@1300nm | - | - | ≥1000MHz·km | ≥600MHz·km | |
Cable cut-off wavelength | ≤1260nm | ≤1260nm | - | - | |
Polarization mode dispersion | Single fiber | ≤0.20ps/√km | ≤0.20ps/√km | - | - |
Link value (M=20, Q=0.01%) | ≤0.10ps/√km | ≤0.10ps/√km | - | - |
Technical Parameters
project | content | Numerical value | |||
Number of fiber cores | 2 | 4 | 8 | 12 | |
Reference outer diameter | mm | 11.5 | 15.0 | 25.0 | 33.0 |
Tight set | material | LSZH | |||
Outer diameter mm | (0.6/0.9) ± 0.05 | ||||
Subunit reinforcement | material | Good luck | |||
Subunit sheath | Outer diameter mm | 2.0±0.1 | |||
Wall thickness mm | ≥0.3 | ||||
Single conductor DC resistance | (Ω / 100m) | 13.3 | |||
Feeder | Conductor cross-sectional area mm2 | 1.5 | |||
Center reinforcement | material | FRP | |||
Possible bag | material | Polyester tape, polyester non-woven bag, water blocking tape or other suitable tape | |||
Outer sheath | material | LSZH / PVC / TPU / PE | |||
range of working temperature | °C | -40 ~ +70 | |||
pull | Short/long term N | 1000/500 | |||
Squash | Short/long term N | 2000/1000 | |||
* Fiber color and chromatogram are formulated according to the labeling table. *The number of fibers and feeder specifications can be changed according to customer needs. *The outer diameter and weight of the cable are typical values in the table, and different structural design values will change. |
Main mechanical and environmental properties
project | Inspection standards | Specified value | Claim |
Stretch | IEC 60811-1-1 | See technical parameters | Additional attenuation ≤0.03dB |
Squash | IEC 60811-1-1 | See technical parameters | Additional attenuation ≤0.03dB |
Repeated bending | IEC 60811-1-1 | Load 40N 15 times | Additional attenuation: single mode ≤ 0.4dB; multimode ≤ 0.6dB |
Reverse | IEC 60811-1-1 | Load 40N 10 times | Additional attenuation: single mode ≤ 0.4dB; multimode ≤ 0.6dB |
Temperature cycle test | IEC 60794-1-2-F1 | -40°C ~+70°C | Additional attenuation: single mode ≤0.5dB; multimode ≤0.3dB |
Voltage test | IEC 60227-1 | Apply voltage DC2.5Kv, 5min | Each wire is shielded from the remaining core wires or each wire and the remaining core wires without breaking down. |
Insulation resistance | IEC 60227-1 | +20℃,DC 500v,1min | Insulation resistance between each wire and the remaining core wire or after shielding each wire from the remaining core wire ≥10MΩ*km |
Combustion performance | IEC 60332-1-2 | Flame retardancy | Should be able to pass a single vertical burning |
Smoke density | Light transmittance is not less than 50% | ||
Corrosive | When burning, the gas PH≤4.3, the conductivity should be ≤10μs/mm | ||
* All fiber attenuation changes are monitored at a wavelength of 1550 nm. |
Packaging and delivery length
Standard wooden plate
Delivery length nominal value: 1km or 2km, can also be other delivery length
Copyrignt © 2019 RENDER All rights reserved . Shandong Yibo Photoelectric Technology Co., Ltd.