Category List
Fiber composite low voltage cable
  • Fiber composite low voltage cable
  • message
    details

    Fiber composite low voltage cable

    Optical fiber composite low-voltage cable (OPLC) optical fiber cable and cable are integrated into one, "one cable simultaneous transmission" power flow and information flow, creatively compounding communication optical cable and power cable, realizing terminal power supply and information transmission Dual function. It is a cable that combines optical units in a low-voltage power cable and has power transmission and optical communication transmission capabilities. It is suitable for voltage ratings of rated voltages of 0.6/1.0kv and below.


    Features and applications


    ● The cable part and the cable part are kept relatively independent structure, which is convenient for introduction, extraction and connection during installation;


    ● Photoelectric integrated transmission medium to avoid secondary wiring and save construction costs;


    ● Smart grid construction, fiber optic homes in urban residential quarters and buildings.


    Fiber characteristics


    G.652.D

    G.655

    50/125μm

    62.5/125μm

    attenuation

    @850nm

    -

    -

    ≤3.0dB/km

    ≤3.0dB/km

    @1300nm

    -

    -

    ≤1.0dB/km

    ≤1.0dB/km

    @1310nm

    ≤0.36dB/km

    ≤0.36dB/km

    -

    -

    @1550nm

    ≤0.22dB/km

    ≤0.23dB/km

    -

    -

    bandwidth

    @850nm

    -

    -

    ≥500MHz·km

    ≥200MHz·km

    @1300nm

    -

    -

    ≥1000MHz·km

    ≥600MHz·km

    Cable cut-off wavelength


    ≤1260nm

    ≤1260nm

    -

    -

    Polarization mode dispersion

    Single fiber

    ≤0.20ps/√km

    ≤0.20ps/√km

    -

    -

    Link value(M=20,Q=0.01%)

    ≤0.10ps/√km

    ≤0.10ps/√km

    -

    -

    Technical Parameters

    project

    content

    Numerical value

    specification

    2-24B1.3+3*1.5mm²

    2-24B1.3+3*4.0mm²

    2-24B1.3+3*6.0mm²

    Light unit

    Number of loose tubes * number of cores per die

    4*6

    4*6

    4*6

    Outer diameter

    1.75

    1.75

    1.75

    Feeder

    material

    Copper wire



    Number of cores * cross section(mm²)

    2*1.5

    2*4.0

    2*6.0

    Reference outer diameter

    mm

    15.5

    16.0

    18.0

    Water blocking material

    material

    Water blocking cable

    Inner sheath


    thickness(±0.1mm)

    0.9

    Armor layer

    material

    Steel belt armor

    Outer sheath


    thickness(±0.2mm)

    1.8

    Operating temperature

    -40 - +70

    Flattening force

    Short/long term(N)

    1000/300

    * 2*1.5 indicates the number and specifications of conductors; 2-24B1.3 identifies the number and specifications of fiber cores;


    *The cross-sectional area and the number of cores can also be customized according to customer requirements.


    Main mechanical and environmental properties

    project

    Inspection standards

    Specified value

    Claim

    Stretch

    IEC 60794-1-2-E1

    See technical parameters

    Short-term additional attenuation: ≤0.1dB

    Squash

    IEC 60794-1-2-E3

    See technical parameters

    Short-term additional attenuation: ≤0.1dB

    Shock

    IEC 60794-1-2-E4

    Height 1 m, hammer 450g, impact cross-sectional area 12.5mm2; 5 times

    Residual additional attenuation: ≤0.03dB

    Reverse

    IEC 60794-1-2-E7

    1 meter ±180° 10 times

    Residual additional attenuation: ≤0.03dB

    Temperature cycle test

    IEC 60794-1-2-F1

    -40°C +70°C

    Additional attenuation change: ≤0.05dB/km

    * All fiber attenuation changes are monitored at a wavelength of 1550 nm.

    Packaging and delivery length


    Standard wooden plate


    Delivery length nominal: 2km or 3km, but also other delivery lengths.


    Ordering information

    SPFO

    OPLC

    -□□+□*□

      1  2   3   4

    1 fiber core number:

    2~288

    2 fiber type:

    B1.3(G652D) /B4(G655)



    A1a(50/125)/A1b(62.5/125)

    3 feeder number:

    2~4

    4 Feeder cross-sectional area:

    1.5~500mm²